CRIUS V6
NORTHERN MEDITEC
The Crius V6 is an electric, electronically controlled, mechanically ventilated ventilator that combines invasive, non-invasive and high flow oxygen therapy ventilation for a wider range of patients with severe respiratory disorders.
Product Details
Comprehensive & Powerful Ventilator
High-end mechanical ventilator from Northern Meditec. A wide range of standard features and options allows you to fit the Crius V6 to your needs.
Turbine Based
Shorter triggering and inspiratory delay
Powerful non-invasive ventilation
Compressor Free
Central Gas Free
Less Cost
Control
Crius V6 is a fully electronic control ventilator
Tidal Volume
5-2000mL (Optional 2-2000mL)
A wide range of TV adjustments allow the medical team to tailor the ventilator to multiple types/needs of patient, even with NICU patients
Ventilation Modes
Invasive Ventilation Modes:
VC-ACV, PRVC, SIMV-PRVC, PC-Dual PAP, PC-APRV, nCPAP, CPAP/PSV, CPAP/VG, AMV/MMV,
Apnea Ventilation
HFNC
Non - Invasive Ventilation Modes:
PC-ACV, PRVC, SIMV-PRVC, PC-Dual PAP, PC-APRV, nCPAP, CPAP/PSV, CPAP/VG, AMV/MMV,
Apnea Ventilation
HFNC
Tools
Rlung, RSBI, P0.1, PEEPi, V-CO2, PTP, Expiratory Hold, sign, ATC, PCVR, PPS, Compliance, Calibration, O2 suction, 100% O2 and more adding
Screen Freeze and Lock
Lung Measurement tools: 3 loops;
Multi-Clinical Demands:
Departments: ICCU, CCU, PACU, NICU, OR, In-Hospital Transport, etc..
Suitable for:
Adult and pediatric intensive care
Neonatal intensive care
Critical care transport
Long-term acute care
Neonatal sensor (optional accessories)
The minimum tidal volume is 2mL. It is suitable for newborns and even premature infants to avoid barotrauma;
Meet the needs of patient of different ages, provide individualized treatment, more accurate and safer.
Standard EtCO2 and SpO2 interfaces
EtCO2 showed the concentration of CO2 in blood during ventilation, reflecting the effect of ventilation; It is an important index to judge hyperventilation or hypoventilation.
SpO2 can directly Visual display the concentration of blood oxygen; It is an important index to judge the function of ventilation and air change.
Double index real-time monitoring at the same time, more convenient, more intuitive, more secure.
High and Low Pressure Oxygen interface
The low pressure oxygen interface can be connected to the hyperbaric oxygen cylinder or the central oxygen supply, so that the ventilator can provide sufficient oxygen for patients when ensuring the breathing of mild and severe patients, so as to improve the oxygenation of patients.
The independent low-pressure oxygen interface can be connected to the oxygen pillow or small oxygen bottle to facilitate the hospital transportation and ensure the safety of patients.